Overview---SITRANS FS130 with SITRANS FST030 transmitter and FSS100 sensors
SITRANS FS130
Engineers can use SITRANS FST030 together with FSS200 clamp - on sensors and with the FSS100 inline sensors. Please order the FSS100 7ME381 sensors for the SITRANS FST030 separately.
The SITRANS FST030 transmitter delivers true multi-parameter measurements i.e. volume flow, standard volume flow, density, mass flow, fluid sound velocity and temperature. The multiple outputs and bus communication allow operators or relevant systems to read all primary process information either instantaneously (with a 10 - ms update) or periodically as plant operations require.
The SITRANS FST030 can be used with the FSS100 sensors (SONOKIT).To get a SITRANS FS130 system, the SITRANS FST030 transmitter and FSS100 sensors must be ordered separately. Engineers test and perform quality control on each FSS100 sensor individually. Also, you don't need to pair or calibrate the FSS100 sensors with an FST030 transmitter.
The transmitter related to this system is the SITRANS FST030 (see Technical specifications for SITRANS FST030).
Process value
- Volume flow
- Mass flow
- Flow velocity
- Sound velocity
- Density
- Kinematic viscosity
- Pressure
- Medium temperature
- Totalizer 1 and Totalizer 2
- Totalizer 3
Benefits---SITRANS FS130
Flow calculation and measurement
- Dedicated volume flow calculation with DSP technology
- 100 Hz update rate for all output on all primary process values
- Maximum data age from sensor to output is 20 ms
- Independent low flow cut-off settings for volume and mass flow, standard volume flow and velocity
- Zero-point adjustment on command from discrete input or host system
Operation and display
User-configurable operation display:
- Full graphical display 240 × 160 pixels with up to 6 programmable views
- Self-explaining alarm handling/log in clear text
- Help text for all parameters appears automatically in the configuration menu
Sensor Flash technology stores production specific system documentation and provides removable memory of all flowmeter setups and functions:
- Factory certification
- Non-volatile memory backup of operational data
- Transfer of user configuration to other flowmeters
- 8 GB SD card for storage and data logging
- Audit trail of all parameter changes
- Alarm logging
Alarms and safety
- Advanced diagnosis and service menu enhances troubleshooting and meter validation
- Configurable upper and lower alarm and warning limits for all process values
- Alarm handling can be selected between Siemens and NAMUR standard configurations
Outputs and control
Monitoring comprising of 3 individually configurable totalizers.
Multi-parameter outputs, configurable outputs assigned individually to any of the following parameters:
- Volume flow
- Standard volume flow
- Mass flow
- Flow velocity
- Sound velocity
- Density
- Process viscosity
- Process pressure
- Process/medium temperature
Up to six I/O channels are configured as follows.
Channel 1
Channel 1 is 4 to 20 mA analog output with HART 7.5. You can configure the current signal for mass flow, volume flow. Also, you can select the availability of active or passive function by wiring on the non - Ex terminals.
Channel 2
Channel 2 is a signal output which can be freely configured for any process variable:
- Analog current (0/4 to 20 mA)
- Frequency or pulse
- Operational and alarm status
Channels 3 and 4
Channels 3 and 4 can be ordered with signal (freely configured for any process variable) or relay outputs, or signal input.
Signal output
Signal output can be user configured to:
- Analog current (0/4 to 20 mA)
- Frequency or pulse
- Redundant frequency or pulse (linked to channel 2)
- Operational and alarm status
Signal input
Signal input can be user configured for:
- Totalizer reset functions
- Force outputs or freeze process values
- Initiate automatic zero point adjustment
Relay
Relay output(s) can be user configured to:
- Alarm status
Channels 5 and 6 (with internal DSL)
- RTD temperature inputs for 1000, 500 or 100 Ω RTD's 2-, 3- or 4-wire RTD's supported
- Channels 5 and 6 (with external DSL option)
- RTD temperature inputs or 4-20 ma inputs. Selectable in menu
Approvals and certificates
Siemens designed the SITRANS FST030 transmitter to comply with or exceed the requirements of international standards and regulations.
Design
Engineers design the SITRANS FST030 in an IP67/NEMA 4X aluminum enclosure with a corrosion - resistant coating. Users can mount it on a wall or pipe. They can lock the enclosure with a padlock or wire it with lead security seals. The design team includes all flow and DSL functions integrated into one unit.
The FST030 is available as standard with one current, HART 7.5 output and can be ordered with additional input/output functions.
The SITRANS FST030 wall mount housing transmitter has a modular design with discrete, replaceable electronic modules and connection boards to maintain separation between functions and facilitate field service. All modules are fully traceable and their provenance is included in the transmitter setup.
SensorFlash
SensorFlash is a standard, 8 GB micro SD card with the ability to be updated by PC. It is supplied with each transmitter and comes with a complete set of certification documents including report if ordered. Factory conformance certificates are optional at ordering.
The Siemens SensorFlash memory unit offers the following features and benefits:
- Copy site setups to SD card for easy transfer to other similar transmitters
- Permanent database of operational and functional information from the moment that the flowmeter is switched on
- Users can download new firmware updates from the Siemens internet portal for Product Support. Then, they can place the updates onto SensorFlash (after unmounting it from the transmitter and inserting it into a PC’s SD card slot). After that, they can insert the updated firmware into the existing flowmeter to upgrade the system and the firmware.
SITRANS FST030 industrial housing
Separate field enclosure with modular design. The FST030 can installed direct in the field. The SITRANS FST030 use always the seperate FS DSL for the sensor connection.
Function
The following functions are available:
- Up to four configurable outputs and 2 RTD input channels selected at ordering
- Outputs can be individually configured for mass flow, volume flow, etc.
- Three built-in totalizers which can count positive, negative or net flows
- Independent low flow cut-offs, adjustable
- Uni/bidirectional flow measurement
- Flow direction adjustable
- Alarm system consisting of alarm-log, alarm pending menu
- Change log, logs all changes made to menu parameters or via communications
- Internal data logger
- Display of operating time with real-time clock
- Flowrate outputs are freely configurable between maximum negative and maximum positive flows according to the sensor capacity
- Limit switches programmable for flow, density and temperature. Limit points can be graded as warning and alarm for values both above and below nominal process conditions
- Zero adjustment menu, with zero point evaluation display
- Full service menu for effective and straight forward application and meter troubleshooting
- Precise temperature measurement ensures optimal accuracy on massflow and density
- Fully compatible with Siemens PDM version 8.2 service pack 1 or higher