Description
SITRANS FUS380
SITRANS FUS380 Mains or battery-operated ultrasonic In-Line flowmeter, diameter DN 50 to DN 1200 (2" to 48"). Suitable for volume flow measurement of liquids , for applications in district heating plants, local networks, boiler stations, chiller plants and water applicationsOverview---SITRANS FUS380
Engineers design the 2 - path flowmeter SITRANS FUS380 to be powered by battery or mains. They create it to measure water flow in district heating plants, local networks, boiler stations, substations, chiller plants (including glycol mixes), and other general water applications.
Siemens name the type - approved flowmeter version SITRANS FUE380.
Technically, the meter types SITRANS FUS380 and SITRANS FUE380 are completely identical, only difference is the calibration limit and the type approval for custody transfer.
Benefits---SITRANS FUS380
- Battery-powered up to 6 years
- 115/230 V mains-powered with back-up battery option in case of mains power failure
- Fast measuring frequency 15 Hz/0.5 Hz (230 V AC/Battery)
- Easy one-button straight forward display
- 2-path measuring principle for optimum accuracy
- Compact or remote mounting
- Measures on most district water qualities and water conductivities
- No pressure drop
- Long-term stability
- 2 galvanically isolated digital outputs for easy connection to a calculator (potential-free)
- Analog output 4 to 20 mA
- Bidirectional measurement, with 2 totalizers and outputs
- Dynamic range qi (min) : qs (max) up to 1:400
Application---SITRANS FUS380
The main application for SITRANS FUS380 is measurement of water flow or water flow in energy meter systems in district heating networks or chilled water (including glycol mixes).
Design
The 2-path design of SITRANS FUS380 ensures maximum accuracy under short inlet conditions. The flowmeter consists of a flow sensor pipe, 4 transducers/transducer cables and a transmitter SITRANS FUE080.
The unit is available in a compact or a remote version. Both versions are pre-mounted with short coax-cables. Remote transmitter up to a distance of 30 m by one Sensor link cable (SSL).
Compact mounting is only possible up to 120 °C (248 °F). The sensor must be isolated to protect transmitter from heat. The transmitter is available in an IP67/NEMA 4X/6 enclosure.
Function
Together with the SIMATIC PDM tool the FUS380 offers the possibility of testing and verifying the flowmeter on site and creating a printed ”Qualification Certificate” with specific data that defines the quality status of the measurement.
The Qualification Certificate shows information about the actual status of the flowmeter:
- General settings, flowmeter and battery information, totalizer values, and pulse output settings
- Detailed information about the transmitter and the sensor functionality, and a main parameter list for evaluating the functionality of the flowmeter
Integration
Discover more from SIEMENS
Subscribe to get the latest posts sent to your email.
Reviews
There are no reviews yet.