Description
SITRANS FCT020 Coriolis Flow Transmitter
Overview---SITRANS FCT020
FCT020 is the standard transmitter, suitable for general purpose applications. It delivers accurate and precise measurements of mass flow rate, density, temperature and volume flow rate.
The FCT020 transmitter is available in compact or remote design and can be combined with all SITRANS FC sensors. The selection is made within the complete SITRANS FC ordering code.
Spare transmitters are selected using the SITRANS FC ordering code, but with no sensor selected.
Features
- Multilingual wizard for easy setup and guidance through the main configuration
- Event Management as unique and useful support to run the process effectively and safely
- Data mobility provided by microSD card for easy transfer to other devices for fast setup or to pc for in-depth process analysis or remote service
- Widest range of I/O combinations in the market for most flexible adjustment to the existing system periphery
- Universal power supply to install the device anywhere in the world
- Hart, Modbus communication
- NAMUR NE95 compliance, SIL 2 and SIL 3 compliance
Cable specifications
For remote type devices, an interconnecting cable must be used to connect the sensor to the transmitter. The device specifications, stated in this document, are valid only if one of the original SITRANS FC interconnecting cables is used.
Standard cable length options are specified up to 30 m are specified in the order code to maintain the stated specifications. Cables longer than 30 m (98 ft) are available but must be ordered as separate items. For further details, please contact your regional Siemens Measurement Intelligence team.
Digital communicationsEach transmitter is configured with one default digital communication interface, selectable in the SITRANS FC order code.
HART
- When selected, HART communication is supplied on the output terminal pair I/O 1.
- Up to 3 further input/output options can be configured for output terminal pairs I/O 2, I/O 3, and I/O 4.
- HART is available with either non-intrinsically safe or intrinsically safe outputs.
PROFIBUS PA
- When selected, PROFIBUS PA communication is supplied on the output terminal pair I/O 1.
- PROFIBUS PA interface is available with and without intrinsic safety.
- PROFIBUS PA digital communication signal is in accordance with IEC 61158/61784.
- Maximum voltage and correct polarity must be observed for wiring.
- Power supply: 9 ... 32 V DC
- Current draw: 15 mA (maximum)
- Compliance with PA profile revision 3.02 supporting: Condensed Status (NE107)
- Device identification number (IDENT_NUMBER) adaption
Discover more from SIEMENS
Subscribe to get the latest posts sent to your email.
Reviews
There are no reviews yet.